![Spirit flow-x Скачать руководство пользователя страница 177](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386177.webp)
Flow-X─ Function Reference
4-177
Flow-X General functions - fxBatchMin
fxBatchMin
Description
The function determines the minimum for a particular input value over a batch.
A batch can be any batch type of process, such as product loading, meter proving or transmitter
validation.
Inputs and outputs
Function
inputs
Remark
EU
SW tag
Range
Default
Name
Name used for tag-prefix and
retentive storage.
Input value
Value for which the minimum
has to be determined
Same as
linked cell
-1e11..1e11
Enabled
0: Disabled
1: Enabled
EN
Reset
command
Trigger to reset the batch.
At a batch reset the current
average is stored in the
previous value and the current
value is reset to 0
Identification
Batch identification.
Can be any string of maximum
255 characters long.
If multiple identifications need
to be stored for future referral,
e.g. the batch number, the ship
name and the nomination
number, then the individual
strings should be concatenated
with an "." character in-
between.
ID
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Current
minimum
Minimum over the
current batch.
Same as input
‘Input value’
CB
0
Previous
minimum
Minimum over the
previous batch.
Same as input
‘Input value’
PB
0
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...