Flow-X─ Function Reference
4-285
Flow-X General functions - fxSolartron_Gas_M
correction is enabled and the
G value method is 'Use input G
value'
Specific gravity
Value will be used when VOS
correction is enabled and the
G value method is 'Use ratio of
inputs'
-
SG
0..2
0
Ratio of specific
heats
Value will be used when VOS
correction is enabled and the
G value method is 'Use ratio of
inputs'
-
CP_CV
0..10
0
Function outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of
range
2: Calculation error
STS
FIOOR
CALCERR
Corrected density
Density corrected for
temperature and VOS
kg/m3
CORDENS
0
Density corrected for
temperature
Density corrected for
temperature
kg/m3
TCORDENS
0
Uncorrected density
Uncorrected (indicated
density
kg/m3
UNCDENS
0
Calculations
The uncorrected density ρ
i
is calculated by
2
2
1
0
K
K
K
i
Where:
ρ
i
The uncorrected density
kg/m3
K0
Obtained from the calibration certificate
-
K1
Obtained from the calibration certificate
-
K2
Obtained from the calibration certificate
-
τ
The time period in µs
s
The temperature corrected density ρt is calculated by
R
R
i
t
t
t
K
t
t
K
19
18
1
Where:
ρ
t
The density corrected for temperature
kg/m3
K18
Obtained from the calibration certificate
-
K19
Obtained from the calibration certificate
-
t
The line temperature
°C
t
R
The reference temperature
°C
The density value corrected for Velocity of Sound is calculated as follows:
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...