Flow-X─ Function Reference
4-257
Flow-X General functions - fxPeriodMin
fxPeriodMin
Description
The function determines a minimum value over a particular period.
Inputs and outputs
Function
inputs
Remark
EU
SW tag
Range
Default
Name
Name used for tag prefix and
retentive storage.
Input value
Value for which the minimum
has to be determined
Same as
linked cell
Enabled
0:
Disabled
<> 0:
Enabled
EN
Period type
Type of period:
1: Second
2: Minute
3: Hour
4: Day
5: Week
6: Month
7: Quarter
8: Year
TYP
Period count
Number of periods (e.g. 5
minutes, 8 hours)
CNT
1..1e11
Period start
Absolute start date and time
of the period. This will be
used as the reference point to
calculate the next period
rollover from.
The value may be defined in
the past or the future. The
next rollover period will be
calculated accordingly (so
forwards or backwards in
time).
START
<DATETIME>
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Current
minimum
Minimum over the
current period.
Same as
input ‘Input
value’
CUR
0
Previous
minimum
Minimum over the
previous period.
Same as
input ‘Input
value’
PRV
0
Pre-
previous
maximum
Minimum over the
pre-previous period
(i.e. period before the
previous period).
Same as
input ‘Input
value’
PPRV
0
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...