![Spirit flow-x Скачать руководство пользователя страница 237](http://html1.mh-extra.com/html/spirit/flow-x/flow-x_function-reference_1348386237.webp)
Flow-X─ Function Reference
4-237
Flow-X General functions - fxISO6976_1983_M
fxISO6976_1983_M
ISO standard 6976 defines component properties and calculations to determine the calorific value,
density and relative density for a gas composition at the specified metering and combustion reference
temperatures and 1.01325 bar(a).
Compliance
International standard, Natural Gas - Calculation of calorific values, density, relative density
and Wobbe index (ISO 6976:1983)
Boundaries
ISO6976:1983 does not define limits for its input data.
Function inputs and outputs
Function inputs
Remark
EU
Range
Default
Name
Optional tag name, tag description and
tag group
Composition
Standard composition as defined in
section 'Standard gas composition.
mol/mol
0..1
0
Metering reference
temperature
Temperature used for calculating the
compressibility, the density and the real
relative density values
1: 0 °C
2: 15 °C
-
1
Calorific value reference
temperature
Temperatures used for calculating the
calorific values.
1st value represents the combustion
reference temperature and the 2nd
value the Gas volume reference
temperature
1: 25 °C / 0 °C
2: 0 °C / 0 °C
3: 15 °C / 0 °C
4: 15 °C / 15 °C
5: 60 °F / 60 °F
-
1
Function outputs
Remark
EU
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: Mole fractions do not add up to 1.0 +- 0.0001
Superior calorific value
Real value at the reference conditions of
temperature and pressure
MJ/m3
0
Density
At the reference conditions of temperature and
pressure
kg/m3
0
Compressibility
-
1
Relative density
-
0
Molar mass
kg/kmol
0
Calculations
Calculations are performed in accordance with the standard, using the values as listed in the tables of
the standard.
Содержание flow-x
Страница 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Страница 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Страница 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Страница 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...