6 Alarms
11.03
6.1 Alarms for SINUMERIK 840digital
© Siemens AG 2003 All Rights Reserved
6-334
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
27201
PROFIsafe: MD %1[%2]: Bus segment %3 error
Parameter
%1 = MD name
%2 = MD field index
%3 = Parameterized bus segment
Explanation
An incorrect bus segment was entered in the specified machine data. The value
must be 5.
Response
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy Correct
the
MD.
Program continuation
Power-down the control and power-up again.
27202
PROFIsafe: MD %1[%2]: Address %3 error
Parameter
%1 = MD name
%2 = MD field index
%3 = Parameterized PROFIsafe address
Explanation
An incorrect PROFIsafe address was entered in the specified machine data.
The value must be greater than 0.
Response
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy Correct
the
MD.
Program continuation
Power-down the control and power-up again.
27203
PROFIsafe: MD %1[%2]: Wrong SPL assignment
Parameter
%1 = MD name
%2 = MD field index
Explanation
The parameterization in the specified MD for the connection between the
SPL interface and a PROFIsafe module is incorrect. The reasons for this are as
follows:
- bit limits interchanged (upper bit value < lower bit value)
- bit values greater than in the definition of the SPL interface (bit value > 64)
- number of bits too high for this PROFIsafe module (upper bit value – lower bit
value + 1> 8)
- no SPL assignment was parameterized (both bit values are equal to zero)
- incorrect SPL assignment (bit value equal to zero)
Response
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy Correct
the
MD.
Program continuation
Power-down the control and power-up again.