3 Safety-Related Functions
11.03
3.7 Safe software cams (SN)
© Siemens AG 2003 All Rights Reserved
3-122
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
I/O number for the signal "SG selection bit 1":
6
I/O number for the signal "SG selection bit 0":
7
If the axis is positioned exactly at the parameterized cam position, the cam
signals may have different states owing to variations in the actual values
between the two monitoring channels. If the SGAs "SNx" were directly
connected to the SGEs "SG selection", a crosswise data comparison would
signal an error. When cam synchronization is activated, the cam signals are
output with the same signal states in both channels when in the steady-state
condition.
Note
Machine data for the safely-reduced speed function are described in
Chapter 4.
Table 3-46
Supplying MD for cam positions
For 840D
For 611 digital
MD No.
Value
MD No.
Value
SN1- 36937
300
1337
[
0
]
300 000
SN1+ 36936
600
1336
[
0
]
600 000
Table 3-47
Supplying MD for speed limit values
For
840D
For
611
digital
Limit value MD No.
Value
MD No.
Value
1
36931
[
0
]
1000
1331
[
0
]
1000
2
36931
[
1
]
0
1331
[
1
]
0
3
36931
[
2
]
2000
1331
[
2
]
2000
4
36931
[
3
]
4000
1331
[
3
]
4000
Table 3-48
Assigning speed limit values to the zones
Speed limit value
Area
Remarks
SG
selection
Bit 1
Bit 0
1 0
0
1 SG1
active
2 0
1
- Not
used
3 1
0
2 SG3
active
4 1
1
3 SG4
active
Table 3-49
Supplying MD for SGEs/SGAs for 840D
Signal Assignment
SGE/SGA Name
MD
No.
Value
SGA
SN1+
36988[0]
01 09 02 07
SGA
SN1-
36989[0]
01 09 02 06
SGA
Axis safely referenced
36987
01 09 02 05
SGA
SBH/ SG active
36980
01 09 02 04
SGE
SBH/SG de-selection
36970
01 09 01 02
SGE
SBH de-selection
36971
01 09 01 03
SGE
SG selection, bit 1
36972[1]
01 09 01 06
SGE
SG selection, bit 0
36972[0]
01 09 01 07