11.03
6 Alarms
6.1 Alarms for SINUMERIK 840digital
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
6-315
11:
Upper limit value SE1. Enter equal MDs.
12:
Lower limit value SE1. Enter equal MDs.
13:
Upper limit value SE2. Enter equal MDs.
14:
Lower limit value SE2. Enter equal MDs.
15:
Safe cam 1+ (+tolerance). Enter equal MDs.
16:
Safe cam 1+. Enter equal MDs.
17:
Safe cam 1- (+tolerance). Enter equal MDs.
18:
Safe cam 1-. Enter equal MDs.
19:
Safe cam 2+ (+tolerance). Enter equal MDs.
20:
Safe cam 2+. Enter equal MDs.
21:
Safe cam 2- (+tolerance). Enter equal MDs.
22:
Safe cam 2-. Enter equal MDs.
23:
Safe cam 3+ (+tolerance). Enter equal MDs.
24:
Safe cam 3+. Enter equal MDs.
25:
Safe cam 3- (+tolerance). Enter equal MDs.
26:
Safe cam 3-. Enter equal MDs.
27:
Safe cam 4+ (+tolerance). Enter equal MDs.
28:
Safe cam 4+. Enter equal MDs.
29:
Safe cam 4- (+tolerance). Enter equal MDs.
30:
Safe cam 4-. Enter equal MDs.
31:
Position tolerance. Enter equal MDs.
32:
Reference position tolerance. Enter equal MDs.
33:
Time, speed changeover. Enter equal MDs.
34:
Tolerance time SGE changeover. Enter equal MDs.
35:
Delay time, pulse cancellation. Enter equal MDs.
36:
Time to test the pulse cancellation. Enter equal MDs.
37:
Transition time, STOP C to SBH. Enter equal MDs.
38:
Transition time, STOP D to SBH. Enter equal MDs.
39:
Transition time, STOP E to SBH. Enter equal MDs.
40:
Stop response after SG. Enter equal MDs.
41:
Stop response after SE. Enter equal MDs.
42:
Shutdown speed after pulse cancellation. Enter equal MDs.
43:
Data save test, stop response.
44:
Actual position value + limit value SG1.
45:
Actual position value - limit value SG1.
46:
Actual position value + limit value SG2.
47:
Actual position value - limit value SG2.
48:
Actual position value + limit value SG3.
49:
Actual position value - limit value SG3.
50:
Actual position value + limit value SG4.
51:
Actual position value - limit value SG4.
52:
Standstill po tolerance.
53: Standstill
position
-
tolerance.
54:
Actual position value "+ nx" + tolerance.
55:
Actual position value "+ nx".
56:
Actual position value "- nx".
57:
Actual position value "- nx" + tolerance.
58: Actual
stop
request.
59:
SG correction factor 1. Enter equal MDs.
60:
SG correction factor 2. Enter equal MDs.
61:
SG correction factor 3. Enter equal MDs.
62:
SG correction factor 4. Enter equal MDs.
63:
SG correction factor 5. Enter equal MDs.
64:
SG correction factor 6. Enter equal MDs.
65:
SG correction factor 7. Enter equal MDs.
66:
SG correction factor 8. Enter equal MDs.
67:
SG correction factor 9. Enter equal MDs.
68:
SG correction factor 10. Enter equal MDs.
69:
SG correction factor 11. Enter equal MDs.
70:
SG correction factor 12. Enter equal MDs.
71:
SG correction factor 13. Enter equal MDs.