4 Data Descriptions
11.03
4.1 Machine data
© Siemens AG 2003 All Rights Reserved
4-228
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
36964
MD number
$MA_SAFE_IPO_STOP_GROUP
Grouping safety IPO response
840D
Default: 0
Min. input value: 0
Max. input value: 1
Change effective after RESET
Protection level (R/W) 7/2
Unit: -
Data type: BYTE
Applies from SW 4.4.18
Meaning
This MD influences the channel-wide IPO stop response distribution of Safety Integrated.
It is only effective for Safety Integrated axes/spindles.
0 =
All other axes-spindles in the channel are notified of the
IPO stop response of this axis (default)
•
1 = For internal STOPs, the axes and machining spindles, interpolating with the
axis involved, are also additionally influenced via the initiated safety alarms. On
the other hand, other axes/spindles in the channel continue to run without
any
disturbance.
For external STOPs (without alarm) all of the other axes/spindles remain
unaffected by the safety axis/spindle stop. This allows, for example, the
pulses of the spindle to be safely cancelled (using an external STOP A) so that
this spindle can be manually rotated and the axis can still be safely monitored
when
moving.
If, in some machining situations, the other axes/spindles should stop together
with the safety/axis/spindle, then the user is responsible in implementing this using PLC or
synchronous action logic combinations.
36965
MD number
$MA_SAFE_PARK_ALARM_SUPPRESS
Suppression of Alarm "Axis not safely referenced" during parking
840D
Default: FALSE
Min. input value: -
Max. input value: -
Change becomes effective after POWER ON:
Protection level (R/W) 7/2
Unit: -
Data type: BOOLEAN
Applies from SW 5.2
Meaning
Enable the suppression of Alarms 27000/300950 "Axis not safely referenced" when the
"Parking" function is selected.
Corresponds with …
36966
MD number
$MA_SAFE_BRAKETEST_TORQUE
Brake test, holding torque
840D
Default: 5%
Min. input value: 0
Max. input value: 800
Change becomes effective after POWER ON:
Protection level (R/W) 7/2
Unit: %
Data type: DOUBLE
Applies from SW 6.3.21
Meaning
Specifies the torque or force for the function test of the brake mechanical system. The
holding brake must be capable of applying this torque without any axis slippage.
Activating the appropriate test function via MD $MA_FIXED_STOP_MODE, bit 1. This MD
must be a minimum of 10 % above the actual torque when selecting the brake test (i.e.
with the brake open). This guarantees that if the brake is defective, the motor can again
brake the axis. If this is not the case, the brake test is aborted with Alarm 20095.
If the drive MD 1192 is not correctly parameterized, then the required safety margin is
increased by twice the margin between the real torque and that parameterized in MD
1192.
36967
MD number
$MA_SAFE_BRAKETEST_POS_TOL
Position tolerance, brake test
840D
Default: 1
Min. input value: 0
Max. input value: -
Change becomes effective after POWER ON:
Protection level (R/W) 7/2
Unit: mm/degrees
Data type: REAL
Applies from SW 6.3.21
Meaning
Maximum position tolerance for the function test of the brake mechanical system. If the
axis position deviates from the position by more than this tolerance, when the brake test is
selected, then the function test for the brake mechanical system is aborted.