11.03
4 Data Descriptions
4.1 Machine data
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
4-229
Note
The maximum input value for all axial NCK_SGE/SGA configuring machine
data differs depending on the application:
Configuring on NCK I/Os: 811E0810
Configuring an SGE on the SPL interface: 84020220
Configuring an SGA on the SPL interface: 84010220
An incorrect entry is detected at the next run-up and flagged with Alarm
27033.
Description of the parameterization of the SGE machine data MD 36970 to
MD 36979
Structure for the input assignment SBH/SG de-selection
is
mm
xx nn Perm.
values
Explanation
i
Inversion
0, 8
0: No inversion
8:
Inversion
before
processing
s
Segment No.
1, 4
1: I/Os on 611 digital bus
(terminal)
4:
Internal
map
in
system
memory
(system
variable)
Further parameterization if one terminal is assigned (s = 1).
mm Module no.
01-1F Number of the logical
slot
in
which
the
terminal block with
external I/Os is inserted
(drive
number)
xx Submodule No.
01-08
Slot number of the sub-
module
inside
the
I/O
module
nn I/O No.
01-10
Bit number (input/output-
number
on
the
submodule
Further parameterization if a system variable is assigned (s = 4).
mm Module No.
01-02
01: Addressing of internal
SPL
interface
$A_OUTSI
or
$A_INSI
02: Addressing of external
SPL interface (only for input
signals,
$A_INSE)
xx Submodule No.
01-02
Index of system variable word
(per
32
bits)
nn I/O No.
01-20
Bit number in system variable
word
$A_OUTSID[xx],
$A_INSID[xx],
$A_INSED[xx]
With each entry, a single bit is assigned to a terminal. The structure
corresponds to MD 10362: $MN_HW_ASSIGN_ANA_FASTIN[n].
Coding of input