4 Data Descriptions
11.03
4.2 Machine data for SIMODRIVE 611 digital
© Siemens AG 2003 All Rights Reserved
4-242
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
4.2.2
Description of the machine data
1300
$MD_SAFETY_CYCLE_TIME
611 digital
Monitoring clock cycle
Relevant for:
FD/MSD
Unit:
31.25 µs
Default:
384 (= 12 ms)
Minimum value:
16
Maximum value:
800
Data type:
short integer
Becomes effective:
POWER ON
This data sets the monitoring clock cycle for safe operation.
Position controller clock cycle <= Monitoring clock cycle <= 25ms
The monitoring clock cycle defines the response time of the monitoring
functions. It should be noted that a short monitoring cycle time increases the
load on the CPU.
1301
$MD_SAFE_FUNCTION_ENABLE
611 digital
Enable safety functions
Relevant for:
FD/MSD
Unit:
Hexadecimal
Default:
0
Minimum value:
0
Maximum value:
FFEB Hex
Data type:
Binary
Becomes
effective:
POWER ON
This data enables the partial functions for safe operation on an axis-specific or
spindle-specific basis. The bit assignment is as follows:
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
High byte
Enable safe cams
SN4 -
SN4 +
SN3 -
SN3 +
SN2 -
SN2 +
SN1 -
SN1 +
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Low byte
Enable
(840D from SW4.2)
Reserved, these bits must be set to 0 Enable
Cam
synchron-
ization
External
STOPs
Override,
safely-
reduced
speed
Enable
external
ESR
activation
Enable
actual
value
synchroniz
ation 2-
encoder
system
Reserved
for
functions
with
absolute
reference
SE SBH/SG
1302
$MD_SAFE_IS_ROT_AX
611 digital
Axis-specific bits for safety-relevant functions
Relevant for:
FD/MSD
Unit:
-
Default:
0
Minimum value:
0
Maximum value:
00 03
Data type:
Binary
Becomes
effective:
POWER ON
Axis and encoder bits related to safety functions.
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
High byte
Reserved, these bits must be set to 0
0 0 0 0 0 0 0 0
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Low byte
Reserved, these bits must be set to 0
0 0 0 0 0 0
Inch
system
Axis type
Bit 0
1:
Rotary axis/spindle
0: Linear
axis
Bit 1
1:
Imperial system (inches etc.)
0: Metric
system: