3 Safety-Related Functions
11.03
3.12 SI I/Os using fail-safe modules connected to PROFIBUS DP (840D from SW 6.3.30)
© Siemens AG 2003 All Rights Reserved
3-182
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
The following software prerequisites must be fulfilled before PROFIsafe
communications can be commissioned and used:
SIMATIC: Creating and loading the configuration
•
SIMATIC STEP 7, from Version V5.1 with Service Pack 6 and Distributed
Safety Integrated V5.2
•
STEP 7 V5.2 and S7-F Configuration Pack V5.3 (can be downloaded free of
charge)
SINUMERIK: Parameterizing NCK and PLC
•
Software release from SW 6.3.30
•
Software option "Distributed I/Os via PROFIBUS DP"
•
Software option "SINUMERIK Safety Integrated safety functions for
personnel and machines"
3.12.4 System
structure
PS_KOMSTRU1.DSF
PROFIBUS-DP
DP-Slave ET 200S
PLC-SPL
PLC
SINUMERIK 840D
Use
r l
ev
el
O
per
at
in
g sy
st
em
le
ve
l
NCK
DP-Slave ET 200S
PROFIsafe comm.
User communication
D
P
cyc
le
OB1
c
yc
le
IPO
c
yc
le
PR
OFI
sa
fe
c
yc
le
DB 18: INSEP/OUTSEP
$A_INSE/$A_OUTSE
DP data
NCK-SPL
PROFIsafe-
Layer
PROFIsafe-
Layer
PROFIBUS-
Layer
P
R
O
F
Is
af
e cyc
le
(O
B
4
0)
PROFIBUS-DP comm.
Fig. 3-47
System structure: SI I/Os using F modules on PROFIBUS DP
Software