TV_Bclose : S5TIME ; //TimeValue -> close brake
TV_FeedCommand : S5TIME ; //TimeValue -> force FeedCommand
TV_FXSreached : S5TIME ; //TimeValue -> Fixed stop reached
TV_FXShold : S5TIME ; //TimeValue -> test brake
END_VAR
VAR_OUTPUT
CloseBrake : BOOL ; //Signal close brake
MoveAxis : BOOL ; //do move axis
Done : BOOL ;
Error : BOOL ;
State : BYTE ; //Error byte
END_VAR
The following table lists all of the formal parameters of the brake test function
Signal Type
Type
Remarks
Start
I
BOOL
Starts the brake test
Quit I
BOOL
Acknowledgement
error
Bclosed
I
BOOL
Checkback input whether close brake is controlled (single-
channel - PLC)
AXIS
I
INT
Axis number of axis to be tested
TimerNo I
TIMER
Timer
from
user
program
TV_Btactiv
I
S5TIME
Monitoring time value -> close brake. Test the axis signal
DBX71.0
TV_Bclose
I
S5TIME
Monitoring time value -> close brake. Check the input signal
Bclosed after the CloseBrake output was set.
TV_FeedCommand
I
S5TIME
Monitoring time value -> output traversing command. Check
travel command after MoveAxis has been set.
TV_FXSreached
I
S5TIME
Monitoring time value -> fixed endstop reached
TV_FXShold
I
S5TIME
Monitoring time value -> test brake
CloseBrake O
BOOL
Request,
close
brake
MoveAxis O
BOOL
Request,
initiate
traversing
Done
O
BOOL
Test successfully completed
Error
O
BOOL
Error has occurred
State O
BYTE
ErrorStatus
Error IDs
State Meaning
0 No
error
1
Start conditions not fulfilled, e.g. axis not in closed-loop control/brake
closed/axis inhibited
2
No NC checkback in the "brake test active" signal when the brake
test is selected
3
No checkback signal "brake applied" using the input signal Bclosed
4
No traversing command output (e.g. axis motion has not been
started)
5
Fixed endstop will not be reached - axis RESET was initiated.
6
Traversing inhibit/approach too slow -> fixed endstop cannot be
reached. Monitoring time TV_FXSreached has expired.
7
Brake is not holding at all (end position is reached)/approach speed
is too high
8
Brake opens during the holding period
9
Error when de-selecting the brake test
10 Internal
error
11