Step 7+8: To interconnect the "infeed ready" signal to further Controller Extensions CX32‑2,
repeat steps 5 and 6 for the CU-Link in question.
See also
For more information, see the List Manual
SINAMICS S120/S150, function block diagrams
2179 to 2195.
7.5.10
Licenses for the SINAMICS Integrated / CX32-2
The following SINAMICS functions are licensed via SIMOTION:
- SINAMICS Safety Integrated Extended Functions for SIMOTION D
SINAMICS Safety Integrated Advanced Functions for SIMOTION D (as of V5.2)
- SINAMICS high output frequency for SIMOTION D
SINAMICS Integrated / CX32-2
SINAMICS Safety Integrated Extended Functions for SIMOTION D
Highly effective protection of personnel and machinery can be implemented with SIMOTION
D thanks to the integrated safety functions of SINAMICS S120. Whereas the Safety Integrated
Basic Functions are license-free, the Safety Integrated Extended Functions and Advanced
Functions require a license for each drive with safety functions.
- SINAMICS Safety Integrated Extended Functions for SIMOTION D or
- SINAMICS Safety Integrated Advanced Functions for SIMOTION D
With the licenses, the Safety Integrated Extended and Advanced Functions are licensed for
drives on the SINAMICS Integrated of a SIMOTION D Control Unit as well as on the CX32-2
Controller Extensions.
Licensing method: License for each drive with Safety Integrated Extended Functions or
Advanced Functions. The Safety Integrated Advanced Functions also include the Safety
Integrated Extended Functions.
Note
Instead of for each drive, the licensing can be performed for all integrated SINAMICS drives
and CX32-2 Controller Extensions with the MultiAxes and Safety Extended Package for
SIMOTION D.
SINAMICS high output frequency for SIMOTION D
Because of legal specifications, the output frequency for converter systems is limited to 550
Hz per default.
- SINAMICS S120 Control Units as of firmware V4.7 HF7
- SIMOTION D Control Units as of firmware V4.4 HF6
Commissioning (software)
7.5 Additional information on configuring the SINAMICS Integrated
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
251