Default Ethernet addresses
The following addresses are assigned by default:
Table 6-8
IP address assignment for a SIMOTION D4x5‑2
Interface
Use case
Default address
X127 P1
PN/IE
Insert SIMOTION device or
HW Config
IP address:
Subnet mask:
Router address:
Automatic private IP ad‐
dress
169.254.11.22
255.255.0.0
0.0.0.0
D4x5‑2 as delivered
IP address:
Subnet mask:
Router address:
Automatic private IP ad‐
dress
169.254.11.22
255.255.0.0
0.0.0.0
X120 P1
PN/IE-OP
(only for D4x5-2 DP)
Insert SIMOTION device or
HW Config
IP address:
Subnet mask:
Router address:
192.168.213.1
255.255.255.0
0.0.0.0
D4x5‑2 DP as delivered
IP address:
Subnet mask:
Router address:
Automatic private IP ad‐
dress
0.0.0.0
0.0.0.0
0.0.0.0
X130 P1
PN/IE-NET
Insert SIMOTION device or
HW Config
IP address:
Subnet mask:
Router address:
192.168.2.1
255.255.255.0
0.0.0.0
D4x5‑2 as delivered
IP address:
Subnet mask:
Router address:
0.0.0.0
0.0.0.0
0.0.0.0
Note
The IP addresses 192.168.215.240 to 192.168.215.255 are reserved for internal
communication in the SIMOTION D4x5‑2 (subnet mask 255.255.255.240). When configuring
the external Ethernet interfaces (X127 P1, X120 P1 and X130 P1), make sure that the internal
addresses are not inside their network. (In IP, the network is defined as an AND link of IP
address and subnet mask.)
Note
If you want to go online via Ethernet, you have to make sure that the connection from PG/PC
to SIMOTION D4x5‑2 is active. You can check this in NetPro. A description of how to switch
a connection to active again can be found in the Section Establishing the PG/PC assignment
Parameter assignment / addressing
6.6 Configuring an Ethernet subnet
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B