7.20
Configuring Safety Integrated functions
7.20.1
Overview
Integrated safety functions
When used in conjunction with SIMOTION D, the integrated safety functions of
SINAMICS S120 provide highly effective practical protection for personnel and machinery.
● Safety Integrated Basic Functions
● Safety Integrated Extended Functions
● Safety Integrated Advanced Functions
Note
As of SIMOTION V5.2 / SINAMICS Integrated V5.1, a distinction is made between Safety
Integrated Extended and Advanced Functions. The Safety Integrated Advanced Functions
also include the Safety Integrated Extended Functions.
The safety functions listed here conform to:
● Safety Integrity Level (SIL) 2 according to IEC 61508
● Category 3 according to DIN EN ISO 13849-1
● Performance Level (PL) d according to DIN EN ISO 13849-1
The safety functions correspond to the functions according to DIN EN 61800-5-2 (if they are
defined there).
Übersicht der Safety Integrated Functions
If motors without a (safety-capable) encoder are being used, not all Safety Integrated Functions
can be used.
Note
Definition: "Without encoder"
When "without encoder" is used in this manual, then this always means that either no encoder
or no safety-capable encoder is being used.
Commissioning (software)
7.20 Configuring Safety Integrated functions
SIMOTION D4x5-2
318
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B