Table 5-10
System variable fannecessary/fanexisting
System variable on the de‐
vice
States
Description
fanbattery of data type StructDeviceFanBattery (the system variables are of the data type EnumFan‐
Battery)
.fannecessary
MANDATORY
Fan is required for operation of the de‐
vice. .fanexisting can be used to query
whether a fan is installed.
Examples: D410‑2, D4x5‑2
OPTIONAL
Fan can be used optionally. .fanexisting can
be used to query whether a fan is installed.
Examples: D425, D435
NOT_MANDATORY
Fan is not required for operation of the de‐
vice.
.fanexisting
1)
SINGLE
Single fan is available.
Examples: D410‑2
REDUNDANT
Double fan is available.
Examples: D4x5‑2
NOT_EXISTING
No fan available.
Example: D425 and D435 without optional
fan
1)
Value for SIMOTION D4x5‑2 is updated dynamically
References
You will find detailed information on setting up Taskstartinfo (#TSI) in the
SIMOTION Runtime
Basic Functions Function Manual.
5.4.4
Response to overtemperature
Operation at overtemperature reduces the module service life and can result in damage to the
module.
Causes
Cause of problems in the heat dissipation of the module can be, for example:
● Violation of the maximum permissible air intake temperature
● Free convection is not ensured (clearances are not maintained, pollution, convection is
prevented by cables)
● Impermissible mounting position of the module