Connector Description
Normalization
Function
diag., Sheet
K0989
Information about torque direction and firing angle
Nibble 0 ..
Torque direction
0 = M0 (--)
1 = MI
2 = MII
9 = The master waits in M0 until all slaves have reached the
RUN state
Nibble 1 ..
Code number for firing angle
1 = Firing angle requested by current conprecontrol
implemented
2 = Firing angle requested by current conprecontrol
was > P151. It has been implemented or limited to 165 °
3 = Alpha-W pulse at 165°
4 = Alpha-W pulse at P151 angle setting
5 = Firing angle requested by current conprecontrol
could not be implemented due to strong pulse compression
6 = Slave connected in parallel could not adapt its computing
cycle to the firing angle of the paralleling master
7 = No firing angle received from paralleling master
8 = The cycle time received from the paralleling master is too
long
9 = The firing angle of the paralleling master has been
implemented
Nibble 2 ..
Code number for requested torque direction
0: Not RUN (
≥
o1.0)
1: Torque direction acc. to current setpoint K119
(==> M0, MI, MII)
2: Wait for enable from parallel drive [acc. to P165] (==> M0)
3: Firing angle of > 165 degrees requested (==> M0)
4: Additional wait time in auto-reversing stage (==> M0)
5: Output 165-degree pulse without second pulse in the old
torque direction (==> MI, MII)
6: Output Alpha-W pulse (as set in P151) without second
pulse in the old torque direction (==> MI, MII)
7: Torque direction request during short-circuit test of thyristor
check function (==> MI)
8: Torque direction request during open circuit test of thyristor
check function (==> M0, MI, MII)
9: The selected thyristor pair is disabled during thyristor check
(==> M0)
A: No
meaning
B: Torque direction of paralleling is being implemented
(==> M0, MI, MII)
C: Simulation operation (==> MI, MII)
[SW 1.8 and later]
D: The command “Fire all thyristors simultaneously“ is being
executed
(see also under P0176)
[SW 1.8 and later]
E: Output 165-degree pulse with second pulse in the old
torque direction (==> MI, MII) (see also P0179)
[SW 1.9 and later]
F: Output Alpha-W pulse (as set in P151) with second pulse in
the old torque direction (==> MI, MII)
(see also P0179)
[SW 1.9 and later]
Nibble 3 ..
Code number for zero current signal
[SW 1.9 and later]
0: The "I=0" signal is not evaluated because no change in
torque direction is required
1: I <> 0
2: I = 0 for less than 0.1 msec
3: I = 0 for more than 0.1 msec
4: I = 0 for more than 0.6 msec
5: Ia-act (K116) is < 1 % for more than 6 current peaks
K0990
Current total processor capacity utilization (C167)
K0991
Projected total processor capacity utilization (C167) for
line frequency = 65 Hz
K0992
Total processor capacity (C167) currently utilized by background routines
Содержание 6RA7013-6DV62
Страница 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 14: ...Safety Information 01 04 1 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 58: ...Shipment Unpacking 01 04 4 2 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 710: ...Connectors and binectors 05 05 12 62 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 726: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 733: ......