Connectors and binectors
05.05
12-4
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
Connector Description
Normalization
Function
diag., Sheet
K0114
Internal signed actual current value (armature), averaged over one firing
cycle
16384
=
∧
100%
G162
K0115
Current controller actual value (armature)
16384
=
∧
100%
G162
K0116
Absolute value of internal actual current (armature)
16384
=
∧
100%
G162
K0117
Internal signed actual current value (armature)
16384
=
∧
100%
G162
K0118
Current controller setpoint (armature)
16384
=
∧
100%
G162
K0119
Current controller setpoint (armature) before absolute-value generation
16384
=
∧
100%
G162
K0120
Current setpoint (armature) before reduced gear stressing
16384
=
∧
100%
G161
K0121
Precontrol output (armature)
16384
=
∧
0°
0
=
∧
90°
-16384
=
∧
180°
G162
K0122
EMF which is applied as an input value for the armature precontrol
(generated from K0123 or K0124 depending on P162, filtered acc. to P163)
16384
=
∧
P078.001
*
3 2
π
G162
K0123
EMF= Ua
−
Ia*Ra
−
La*dia/dt, where the measured armature voltage is applied
as Ua
(Note: K0287 is the result of PT1 filtering with 10ms)
16384
=
∧
P078.001
*
3 2
π
K0124
EMF= Ua
−
Ia*Ra
−
La*dia/dt, where the armature voltage calculated from the
delay angle, measured armature conduction interval and mean line voltage
is applied as Ua. If this calculation cannot be made or is insufficiently
accurate (e.g. with a conduction angle < 10
°
, average armature current value
< 2 % in r072.002), K0124 assumes the value set in K0123.
16384
=
∧
P078.001
*
3 2
π
K0125
Armature current setpoint after reduced gearbox stressing or current setpoint
integrator
G162
Current limitation
K0131
Lowest positive current limit (armature)
16384
=
∧
100%
G161
K0132
Highest negative current limit (armature)
16384
=
∧
100%
G161
K0133
Current setpoint (armature) before limitation (incl. additional setpoint)
16384
=
∧
100%
G161
K0134
Current setpoint (armature) before torque limitation
16384
=
∧
100%
G160
Torque limitation, speed limiting controller
Normalization of torque connectors:
An armature current corresponding to 100% of the converter rated DC current (r072.002) with a motor flux (K0290) corresponding to
100
% of the rated motor field current (P102) produces a torque of 100%.
Note:
Whether connectors K0140, K0141, K0145 and K0147 act as the torque setpoint or the current setpoint depends on P170 (setting
determines which quantity is divided by motor flux).
K0136
Speed limiting controller, active torque limit 1
16384
=
∧
100%
G160
K0137
Speed limiting controller, active torque limit 2
16384
=
∧
100%
G160
K0140
Torque setpoint (after speed limiting controller)
16384
=
∧
100%
G160
K0141
Torque setpoint (after torque limitation)
16384
=
∧
100%
G160
K0142
Actual torque value
16384
=
∧
100%
G162
K0143
Upper torque limit
16384
=
∧
100%
G160
K0144
Lower torque limit
16384
=
∧
100%
G160
K0145
Torque setpoint before limitation (incl. additional setpoint)
16384
=
∧
100%
G160
K0147
Torque setpoint before limitation (without additional setpoint)
16384
=
∧
100%
G160
K0148
Torque setpoint (from speed controller)
16384
=
∧
100%
G152
K0149
Torque actual value related to P100 * P102
[SW 2.0 and later] 16384
=
∧
100%
G162
Содержание 6RA7013-6DV62
Страница 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 14: ...Safety Information 01 04 1 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 58: ...Shipment Unpacking 01 04 4 2 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 710: ...Connectors and binectors 05 05 12 62 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 726: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 733: ......