Parameter list
05.05
11-118
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U223
(2223)
*
S00
(B145)
Source for control signals RESET, TRACK and STORE
FB 82
i001: TRACK
i002: STORE
i003: RESET
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U224
(2224)
*
S00
(B145)
Control word for Power On Mode
FB 82
0 Volatile
storage:
Zero appears at output when voltage recovers
1 Non-volatile
storage:
When the voltage is disconnected or fails, the current output
value is stored and then output when the voltage recovers/is
reconnected
0 to 1
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Tracking/storage element 2
U225
(2225)
*
S00
(B145)
Source for input quantity (x)
FB 83
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U226
(2226)
*
S00
(B145)
Source for control signals RESET, TRACK and STORE
FB 83
i001: TRACK
i002: STORE
i003: RESET
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U227
(2227)
*
S00
(B145)
Control word for Power On Mode
FB 83
0 Volatile
storage:
Zero appears at output when voltage recovers
1 Non-volatile
storage:
When the voltage is disconnected or fails, the current output
value is stored and then output when the voltage recovers/is
reconnected
0 to 1
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Connector memories
The connector memories are memory elements for the input quantities selected via the parameters. The outputs are linked to connectors.
While the SET input is in the log. "1" state, output quantity y tracks input quantity x continuously. If the SET input changes state from log.
"1" to log. "0", the current value of x is stored and output continuously at y.
Output (y) = 0 is set on POWER ON.
Connector memory 1
U228
(2228)
*
S00
(B145)
Source for input quantity (x)
FB 84
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U229
(2229)
*
S00
(B145)
Source for control signal SET
FB 84
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Connector memory 2
U230
(2230)
*
S00
(B145)
Source for input quantity (x)
FB 85
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U231
(2231)
*
S00
(B145)
Source for control signal SET
FB 85
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Содержание 6RA7013-6DV62
Страница 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 14: ...Safety Information 01 04 1 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 58: ...Shipment Unpacking 01 04 4 2 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 710: ...Connectors and binectors 05 05 12 62 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 726: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 733: ......