Parameter list
05.05
11-122
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U262
(2262)
*
S00
(B155)
Source for control signals
FB 100
i001
Source for "Stop integrator" signal
(integrator is stopped when binector reaches log. "1" state)
i002
Source for "Set integrator" signal
(when binector reaches log. "1" state, the integrator is set to the
value entered in parameter U263)
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U263
(2263)
*
S00
(B155)
Source for setting value
FB 100
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Integrator 2
(output = K9221)
U264
(2264)
*
S00
(B155)
Source for input quantity
FB 101
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U265
(2265)
S00
(B155)
Integral-action time
FB 101
10 to 65000
[ms]
1
Ind: None
FS=10
Type: O2
P052 = 3
P051 = 40
Online
U266
(2266)
*
S00
(B155)
Source for control signals
FB 101
i001
Source for "Stop integrator" signal
(integrator is stopped when binector reaches log. "1" state)
i002
Source for "Set integrator" signal
(when binector reaches log. "1" state, the integrator is set to the
value entered in parameter U267)
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U267
(2267)
*
S00
(B155)
Source for setting value
FB 101
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Integrator 3
(output = K9222)
U268
(2268)
*
S00
(B155)
Source for input quantity
FB 102
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U269
(2269)
S00
(B155)
Integral-action time
FB 102
10 to 65000
[ms]
1
Ind: None
FS=10
Type: O2
P052 = 3
P051 = 40
Online
U270
(2270)
*
S00
(B155)
Source for control signals
FB 102
i001
Source for "Stop integrator" signal
(integrator is stopped when binector reaches log. "1" state)
i002
Source for "Set integrator" signal
(when binector reaches log. "1" state, the integrator is set to the
value entered in parameter U271)
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Содержание 6RA7013-6DV62
Страница 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 14: ...Safety Information 01 04 1 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 58: ...Shipment Unpacking 01 04 4 2 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 710: ...Connectors and binectors 05 05 12 62 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 726: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 733: ......