Connections
05.05
6-58
Siemens AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
6.6.2.2.4 Converters 4Q: 460V
Converter
Order No.
C / V
3 line fuses
Siemens
Я
U
3 line fuses
Bussmann
Я
U
3 line fuses
Bussmann
Я
U
Order No.
C / V
Order No.
C / V
Order No.
C / V
A / V
A / V
A / V
A / V
6RA7018-6FV62
30 / 460
3NE1815-0
25 / 690
170M1562
32 / 660
FWH-35B
35 /500
6RA7025-6FV62
60 / 460
3NE1817-0
50 / 690
170M1565
63 / 660
FWH-60B
60 /500
6RA7028-6FV62
90 / 460
3NE1820-0
80 / 690
170M1567
100 / 660
FWH-100B
100 /500
6RA7031-6FV62
125 / 460
3NE1021-0
100 / 690
170M1568
125 / 660
FWH-125B
125 /500
6RA7075-6FV62
210 / 460
3NE3227
250 / 1000
170M3166
250 / 660
FWH-225A
225 /500
6RA7078-6FV62
280 / 460
3NE3231
350 / 1000
170M3167
315 / 660
FWH-275A
275 /500
6RA7082-6FV62
450 / 460
3NE3233
450 / 1000
170M3170
450 / 660
FWH-450A
450 /500
6RA7085-6FV62
600 / 460
3NE3336
630 / 1000
170M4167
700 / 660
FWH-600A
600 /500
6RA7087-6FV62
850 / 460
3NE3338-8
800 / 800
170M5165
900 / 660
FWH-800A
800 /500
Converter
Order No.
C / V
1 DC fuse
Siemens
Я
U
1 DC fuse
Bussmann
Я
U
Order No.
C / V
Order No.
C / V
A / V
A / V
A / V
6RA7018-6FV62
30 / 460
3NE4102
40 / 1000
FWP-35B
35 / 660
6RA7025-6FV62
60 / 460
3NE4120
80 / 1000
FWP-70B
70 / 660
6RA7028-6FV62
90 / 460
3NE4122
125 / 1000
FWP-125A
125 / 660
6RA7031-6FV62
125 / 460
3NE4124
160 / 1000
FWP-150A
150 / 660
6RA7075-6FV62
210 / 460
3NE3227
250 / 1000
FWP-250A
250 / 660
6RA7078-6FV62
280 / 460
3NE3231
350 / 1000
FWP-350A
350 / 660
6RA7082-6FV62
450 / 460
3NE3334-0B
500 / 1000
FWP-500A
500 / 660
6RA7085-6FV62
600 / 460
3NE3336
630 / 1000
FWP-700A
700 / 660
6RA7087-6FV62
850 / 460
3NE3334-0B 1)
500 / 1000
FWP-1000A
1000 / 660
FWH-... and FWP-... fuses are not mechanically compatible with the 3NE... or 170M... fuses.
1) Two fuses connected in parallel
Converter
Order No.
C / V
Branch fuses
Siemens
Я
U
Qty.
Order No.
C / V
A / V
A / V
6RA7091-6FV62
1200 / 460
6
3NE3338-8
800 / 800
Branch fuses are included in converter, external semiconductor fuses are not needed.
6.6.2.3 F1 and F2 fuses in the power interface
Only UL listed or UL recognized fuses must be used for UL listed converters.
Wickmann 198 1A / 250 V 5 x 20 mm time lag
Wickmann 343 1A / 250 V 6,3 x 32 mm time lag
Schurter FSD 1A / 250 V 5 x 20 mm time lag Ordering Code 0034.3987
Schurter FST 1A / 250 V 5 x 20 mm time lag Ordering Code 0034.3117
Содержание 6RA7013-6DV62
Страница 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 14: ...Safety Information 01 04 1 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 58: ...Shipment Unpacking 01 04 4 2 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 710: ...Connectors and binectors 05 05 12 62 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 726: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 733: ......