05.05
Parameter list
SIEMENS AG 6RX1700-0AD76
11-153
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
11.80 Evaluation of a 4-step master switch for cranes
(See also Chapter 8 Function Diagram Sheet G125)
U660
(2660)
*
(G125)
Source for travel command 1
[SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U661
(2661)
*
(G125)
Source for travel command 2
[SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U662
(2662)
*
(G125)
Source for switchover to setpoint step S2
[SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U663
(2663)
*
(G125)
Source for switchover to setpoint step S3
[SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U664
(2664)
*
(G125)
Source for switchover to setpoint step S4
[SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U665
(2665)
(G125)
Setpoint for setpoint step S1
[SW 1.7 and later]
0.00 to 110.00
[%]
0.01%
Ind: None
FS=10.00
Type: O2
P052 = 3
P051 = 40
on-line
U666
(2666)
(G125)
Setpoint for setpoint step S2
[SW 1.7 and later]
0.00 to 110.00
[%]
0.01%
Ind: None
FS=25.00
Type: O2
P052 = 3
P051 = 40
on-line
U667
(2667)
(G125)
Setpoint for setpoint step S3
[SW 1.7 and later]
0.00 to 110.00
[%]
0.01%
Ind: None
FS=40.00
Type: O2
P052 = 3
P051 = 40
on-line
U668
(2668)
(G125)
Setpoint for setpoint step S4
[SW 1.7 and later]
0.00 to 110.00
[%]
0.01%
Ind: None
FS=100.00
Type: O2
P052 = 3
P051 = 40
on-line
11.81 Position/positional
deviation acquisition
Only active with optional technology software S00
U670
(2670)
*
S00
(B152)
Source for actual position values
FB 54
[SW 2.0 and later]
Selection of connector whose values are to be used as actual position
values.
i001: Actual position value 1
i002: Actual position value 2
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 46
i002: 0
Type: L2
P052 = 2
P051 = 40
offline
Содержание 6RA7013-6DV62
Страница 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 14: ...Safety Information 01 04 1 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 58: ...Shipment Unpacking 01 04 4 2 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 710: ...Connectors and binectors 05 05 12 62 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 726: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 733: ......