Parameter list
05.05
11-138
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U431
(2431)
*
S00
(B211)
Source for SET, D, STORE and RESET for D flipflop 2
FB 231
(outputs: Q = B9492, /Q = B9493)
As for U430
All binector numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U432
(2432)
*
S00
(B211)
Source for SET, D, STORE and RESET for D flipflop 3
FB 232
(outputs: Q = B9494, /Q = B9495)
As for U430
All binector numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U433
(2433)
*
S00
(B211)
Source for SET, D, STORE and RESET for D flipflop 4
FB 233
(outputs: Q = B9496, /Q = B9497)
As for U430
All binector numbers
1
Ind: 4
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Timer 1
(0.000 to 60.000s) (output = B9580, inverted: B9581)
U440
(2440)
*
S00
(B215)
Source for input signal and reset signal for timer element 1
FB 240
i001
Source for input signal
i002
Source for reset signal for the pulse generator (if U442=3)
(in state "1", the pulse generator is set to "0")
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U441
(2441)
S00
(B215)
Time for timer 1
FB 240
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U442
(2442)
*
S00
(B215)
Mode for timer 1
FB 240
0 ON
delay
1 OFF
delay
2
ON / OFF delay
3
Pulse generator with positive edge triggering
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 2
(0.000 to 60.000s) (output = B9582, inverted: B9583)
U443
(2443)
*
S00
(B215)
Source for input signal and reset signal for timer element 2
FB 241
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U444
(2444)
S00
(B215)
Time for timer 2
FB 241
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U445
(2445)
*
S00
(B215)
Mode for timer 2
FB 241
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Timer 3
(0.000 to 60.000s) (output = B9584, inverted: B9585)
U446
(2446)
*
S00
(B215)
Source for input signal and reset signal for timer element 3
FB 242
As for U440
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U447
(2447)
S00
(B215)
Time for timer 3
FB 242
0.000 to 60.000
[s]
0.001
Ind: None
FS=0.000
Type: O2
P052 = 3
P051 = 40
Offline
U448
(2448)
*
S00
(B215)
Mode for timer 3
FB 242
As for U442
0 to 3
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
Содержание 6RA7013-6DV62
Страница 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 14: ...Safety Information 01 04 1 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 58: ...Shipment Unpacking 01 04 4 2 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 710: ...Connectors and binectors 05 05 12 62 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 726: ...Environmental compatibility 01 04 16 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Страница 733: ......