91
FC.27
Oscillation suppression
coefficient
1
~
500
1
50
○
FC.28
Oscillation suppression
voltage
0.0
~
25.0%*motor
rated
voltage
0.1%
5.0
○
FD Group – Reserved Parameter
FE Group – Panel Function Setting and Parameter Management
FE.00
LCD language option
(only for LCD panel)
0
:
Chinese
1
:
English
2
:
reserved
1
0
○
FE.01
Key M-FUNC function
0
:
JOG (jog control)
1
:
FWD/REV switch
2
:
clear frequency set by
▲
/
▼
3
:
switch between local operation
and remote control (reserved)
4: reverse
1
0
×
FE.02
Key STOP/RST function
0
:
only effective to panel control
1
:
effective to both panel and
terminal control
2
:
effective to both panel and
communication control
3
:
effective to all control modes
1
3
○
FE.03
STOP + RUN emergency
stop
0
:
disabled
1
:
coast to stop
1
1
○
FE.04
Close-loop
display
0.01
~
100.00
0.01
1.00
○