135
0
~
2
0
0
:
digital setting
Set the target voltage value by function code F5.15.
1
:
AI1
Specify target voltage value by analog quantity AI1, and the corresponding physical quantity F6.00 of AI1 should be
set as 2 (voltage directive).
2
:
AI2
Specify target voltage value by analog quantity AI2, and the corresponding physical quantity F6.00 of AI2 should be
set as 2 (voltage directive).
F5.14
voltage feedback channel of voltage closed-loop output
0
~
1
0
0
:
AI1
Analog quantity AI1 works as voltage feedback input; P6.00 as the corresponding physical quantity of AI1 should be
set as 2 (voltage directive).
1
:
AI2
Analog quantity AI2 works as voltage feedback input; F6.06 as the corresponding physical quantity of AI2 should be
set as 2 (voltage directive).
F5.15
output voltage of digital setting
0.0
~
200.0%*motor rated voltage
100%
F5.16
deviation limit of motor closed-loop adjustment
0.0
~
5.0
%
*motor rated voltage
2.0%
This parameter is used to limit the error amplitude of voltage regulation in close-loop mode, so as to keep the voltage in
the safe range and the equipment working reliably.
F5.17
VF curve max. voltage of half separated mode