241
Data1(2Byte)
13H
88H
Data2(2Byte)
03H
22H
Data3(2Byte)
00H
00H
Data4(2Byte)
13H
88H
CRC CHK High
28H
CRC CHK Low
31H
Analysis of this segment data
:
01H address of the driver
13H write function code
000CH start address, equivalent to F0.12 of control panel
1388H parameter value
0322H attribute value
0000H min.value
1388H max.value
2831H 16 bits of CRC check code
Example
:
Name
Frame format
Read parameter value of
F0.12
Send frame
:
01H 13H 000CH 0001H 85CAH
Return frame
:
01H 13H 02H 1388H B1D2H
Read parameter value +
attribute value of F0.12
Send frame
:
01H 13H 000CH 0002H C5CBH
Return frame
:
01H 13H 04H 1388H 0322H FCE4H