217
Fig. FC-2 AVR Function
LED ten’s place
:
overmodulation
0
:
disabled
1
:
enabled
Overmodulation function means that the driver will boost its bus voltage usage rate to increase output voltage. When it
is enabled, the output harmonic component will increase. This function can be used when the driver works with a heavy
load for a long time or high frequency (over 50Hz) operation torque is insufficient.
LED hundred’s place
:
dead-time compensation
0
:
disabled
1
:
enabled
If it is enabled, dead time compensation of all band will be conducted in all control modes. This function is mainly for
manufacturer debugging, and not recommended to set by customers.
LED thousand’s place
:
harmonic components optimizing
(
reserved
)
0
:
disabled
1
:
Oscillation suppressing mode1