102
power down last time.
1: not save
Once power on, the keypad and terminal frequency increment will be initialized to 0.
LED tens digit: keep when stop
0: keep when stop
When the VFD stops running, the frequency set value stays the last modified value.
1: not keep
When the VFD stops running, the set frequency returns to F0.12.
LED hundreds digit:
UP/DOWN frequency adjustment
0: invalid
1: valid
When valid, operating with key
, terminal UP/DOWN can achieve the positive or negative adjustment of the
frequency.
F0.12
Frequency source digital setting 1
0.00Hz
~【
F0.16
】
upper limit frequency
50.00
When frequency channel is defined as digital given 1 (principle and auxiliary frequency source are both 0), this function
parameter is initial setting frequency given by keypad digital frequency.
F0.13
Frequency source digital setting 2
0.00Hz
~【
F0.16
】
upper limit frequency
50.00
When frequency channel is defined as digital given 2 (principle and auxiliary frequency source are both 1), this function
parameter is initial setting frequency given by VFD terminal.
F0.14
Auxiliary frequency source weight coefficient K setting
0.01
~
10.00
1.00
K is the weight coefficient of auxiliary frequency source, valid when F0.09 is 1~8.