85
FB.05
Transmission response
0
:
response for write operation
1
:
no response for write
operation
1
0
×
FB.06
Ratio
correlation
coefficient
0.01
~
10.00
0.01
1.00
○
FB.07
Communication mode
0
:
general mode
1
:
380 mode
1
0
×
FC Group – Advanced Function and Performance Parameters
FC.00
Dynamic braking
0
:
disabled
1
:
always enabled
2
:
only
enabled
when
decelerating
1
1
×
FC.01
Initial
voltage
of
dynamic braking
220V
:
340
~
380V 360V
380V
:
660
~
760V 680V
1V
Depending
on model
○
FC.02
Hysteresis voltage of
dynamic braking
220V
:
10
~
100V 5V
380V
:
10
~
100V 10V
1V
Depending
on model
○
FC.03
Action ratio of dynamic
braking
10
~
100
%
1%
100%
○
FC.04
Restart after power
failure
0
:
disabled
1
:
start at start frequency
2
:
start in speed tracking mode
1
0
×
FC.05
Restart delay after
power failure
0.0
~
60.0s
0.1s
5.0
×