162
3
:
fault output
The indicator signal output when the VFD fault occurs.
4
:
freq./speed level detection signal (FDT1)
Refer to F7.24
~
F7.26 function description.
5
:
freq./speed level detection signal
(
FDT2
)
Refer to F7.27
~
F7.29 function description.
6
:
freq./speed arrival signal
(
FAR
)
Refer to F7.23 function description.
7
:
indicator during zero-speed running
The indicator signal output when VFD is still in running state and output frequency is 0.00Hz.
8
:
upper limit arrival of output frequency
The indicator signal output when VFD output frequency reached its upper limit.
9
:
lower limit arrival of output frequency
The indicator signal output when VFD output frequency reached its lower limit.
10
:
lower limit arrival of preset frequency
The signal is given if the preset frequency is lower than lower limit during VFD running.
11
:
pre-alarm signal of overload
The signal is given after alarm-delay time (FA.13) if the output current is higher than overload pre-alarm level
(FA.12).
12
:
counter detection signal output
The indicator signal is given when counter detection value arrives, and it is cleared when reset value of counter
arrives. See F7.33.
13
:
counter reset signal output
The indicator signal is given when counter reset value arrives. See F7.32.
14
:
driver ready
This signal is output when the driver has no fault, its bus voltage is normal, the start prohibit function is disabled, so
that the driver is ready to start for direct command.
15: one cycle finished of programmable multi-speed running