192
F9.56
Input method of traverse mode
0
~
1
0
0
:
auto
1
:
terminal config. (manually)
When F9.56 is set at 1, if multi-function terminal selects function NO.35, the driver will enter traverse mode. Otherwise,
traverse is enabled.
F9.57
Amplitude control
0
~
1
0
0
:
fixed amplitude
The reference value of amplitude is max. frequency F0.15.
1
:
varied amplitude
The reference value of amplitude is specified channel frequency.
F9.58
restart method of traverse mode
0
~
1
0
0
:
start to the state before stop
1
:
just restart, no other requirement
F9.59
Save traverse state upon power failure
0
~
1
0
0
:
save
1
:
not save
The traverse state parameters will be saved when poweroff. This function is only effective when “start to the state before
stop” mode is selected.
F9.60
Preset traverse frequency