69
F7.27
FDT2 detection method
0
:
speed set value
1
:
speed detected value
1
0
○
F7.28
FDT2 level
0.00Hz
~【
F0.16
】
upper limit
freq.
0.01Hz
25.00
○
F7.29
FDT2 lag
0.0
~
100.0
%
*
【
F7.28
】
0.1%
4.0%
○
F7.30
Counting value arrival
processing
0
:
stop counting, stop output
1
:
stop counting, resume output
2
:
cycle count, stop output
3
:
cycle count, resume output
1
3
×
F7.31
Counting
start
condition
0
:
always count since power on
1
:
count in operation status,
stop counting in stop status
1
1
×
F7.32
Counter reset value
【
F7.33
】~
65535
1
0
○
F7.33
Counter
detection
value
0
~【
F7.32
】
1
0
○
F7.34
time out processing
0
:
stop timing, stop output
1
:
stop timing, resume output
2
:
cycle timing, stop output
3
:
cycle timing, resume output
1
3
×
F7.35
Timing start condition
0
:
timing starts since power on
1
:
timing starts in operation
status, and stops in stop status
1
1
×
F7.36
Timing setting
0
~
65535S
1s
0
○
F7.37
Y1 turn off delay time
0.0
~
100.0s
0.1s
0.0
×