Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1258
User Manual 1178.8520.02 ─ 08
Manual operation:
See
MMEMory:SELect:CHANnel[:ITEM]:NONE
MMEMory:SELect[:ITEM]:NONE
This command does not include any of the following items when storing or loading a
configuration file.
●
MMEMory:SELect[:ITEM]:HWSettings
●
Limit lines:
MMEMory:SELect[:ITEM]:LINes:ALL
●
●
MMEMory:SELect[:ITEM]:TRACe<1...3>[:ACTive]
Example:
MMEM:SEL:NONE
Manual operation:
See
MMEMory:SELect:CHANnel[:ITEM]:SCData
<State>
MMEMory:SELect[:ITEM]:SCData
<State>
This command includes or excludes source calibration data for an optional external
generator when storing or loading a configuration file.
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Example:
MMEM:SEL:SCD ON
Adds the source calibration data to the list of data subsets.
Manual operation:
See
MMEMory:SELect:CHANnel[:ITEM]:SPECtrogram
<State>
MMEMory:SELect:CHANnel[:ITEM]:SGRam
<State>
MMEMory:SELect[:ITEM]:SPECtrogram
<State>
MMEMory:SELect[:ITEM]:SGRam
<State>
This command includes or excludes spectrogram data when storing or loading a con-
figuration file.
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Example:
MMEM:SEL:SGR ON
Adds the spectrogram data to the list of data subsets.
Manual operation:
See
Managing settings and results
Содержание FSV3000
Страница 1: ...R S FSVA3000 R S FSV3000 Signal and Spectrum Analyzer User Manual 1178852002 Version 08 ÜãD2 ...
Страница 32: ...Contents R S FSVA3000 R S FSV3000 32 User Manual 1178 8520 02 08 ...
Страница 287: ...Measurements and results R S FSVA3000 R S FSV3000 287 User Manual 1178 8520 02 08 Statistical measurements APD CCDF ...
Страница 673: ...Data management R S FSVA3000 R S FSV3000 673 User Manual 1178 8520 02 08 Working with test reports ...