Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
945
User Manual 1178.8520.02 ─ 08
Manual operation:
See
12.5.6.5
Configuring the reference range
The following commands define the reference range for the SEM sweep list.
...................................................................................... 945
[SENSe:]ESPectrum<sb>:FILTer[:RRC]:ALPHa
.................................................................945
[SENSe:]ESPectrum<sb>:FILTer[:RRC][:STATe]
................................................................945
................................................................................946
.................................................................................... 946
[SENSe:]ESPectrum<sb>:BWID
<Bandwidth>
This command defines the channel bandwidth of the reference range.
The bandwidth is available if the power reference is the channel power.
Suffix:
<sb>
.
1 to 8
Sub block in a Multi-SEM measurement
Parameters:
<Bandwidth>
minimum span ≤ value ≤ span of reference range
*RST:
3.84 MHz
Default unit: Hz
Manual operation:
See
[SENSe:]ESPectrum<sb>:FILTer[:RRC]:ALPHa
<Alpha>
This command defines the roll-off factor for the RRC filter.
The RRC filter is available if the power reference is the channel power.
Suffix:
<sb>
.
1 to 8
Sub block in a Multi-SEM measurement
Parameters:
<Alpha>
Range:
0 to 1
*RST:
0.22
Manual operation:
See
[SENSe:]ESPectrum<sb>:FILTer[:RRC][:STATe]
<State>
This command turns the RRC filter in the reference range on and off.
The RRC filter is available if the power reference is the channel power.
Suffix:
<sb>
.
1 to 8
Sub block in a Multi-SEM measurement
Configuring and performing measurements
Содержание FSV3000
Страница 1: ...R S FSVA3000 R S FSV3000 Signal and Spectrum Analyzer User Manual 1178852002 Version 08 ÜãD2 ...
Страница 32: ...Contents R S FSVA3000 R S FSV3000 32 User Manual 1178 8520 02 08 ...
Страница 287: ...Measurements and results R S FSVA3000 R S FSV3000 287 User Manual 1178 8520 02 08 Statistical measurements APD CCDF ...
Страница 673: ...Data management R S FSVA3000 R S FSV3000 673 User Manual 1178 8520 02 08 Working with test reports ...