Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1102
User Manual 1178.8520.02 ─ 08
This function is not available in all applications and measurements.
Parameters:
<Mode>
CSPan | SSTop
CSPan
span / center
SSTop
start / stop frequency
Example:
FREQ:ANN SST
[SENSe:]FREQuency:CENTer
<Frequency>
This command defines the center frequency.
Parameters:
<Frequency>
The allowed range and f
max
is specified in the data sheet.
UP
Increases the center frequency by the step defined using the
DOWN
Decreases the center frequency by the step defined using the
*RST:
fmax/2
Default unit: Hz
Example:
FREQ:CENT 100 MHz
FREQ:CENT:STEP 10 MHz
FREQ:CENT UP
Sets the center frequency to 110 MHz.