Selecting the menu item "I/Q Out Settings" opens a dialog with the parameters for the
I/Q output signal.
The "I/Q Out" Settings dialog is available for analog and digital I/Q output signals.
These dialogs are accessable under the menu sections with the corresponging names.
5.7.3.2
Analog I/Q Output
The differential output of the R&S
SMJ provides symmetrical signals for differential
inputs of DUTs without the need of additional external electric network.
The operating point of the inputs can be set by a definable DC-voltage (bias). In addi-
tion an offset between inverting and non-inverting output can be set to balance a differ-
ence of the best operating points.
The equipment options for the basic unit (R&S
SMJ with frequency option R&S
SMJ-
B10x) include the option R&S
SMJ-B13 (Baseband Main Module) and the option
R&S
SMJ-B16 (Differential Output) for "I/Q Out...".
Option R&S
SMJ-B16 (Differential Outputs) cannot be fitted together with options
R&S
SMJ-B81 (Rear Panel Connectors), because they use the same connectors.
Optimize I/Q Signals for RF Output
Activates/deactivates optimization of level accuracy and imbalance for RF Output.
Level accuracy and imbalance can be either optimized for RF output (active) or for dif-
ferential outputs (not active).
Remote command:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:OPTimization[:RF]:STATe
I/Q Output Type
Selects the type of output. The analog outputs can be operated in "Single Ended"
mode or "Differential" (non-inverted) mode. The menu changes depending on the
selected output mode
Impairment of Digital I/Q Signal and Noise Generator - AWGN/IMP Block
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...