Instrument Function
R&S
®
SMJ100A
276
Operating Manual 1403.7458.32 ─ 14
Dwell Time - List Mode
Enters the dwell time. The dwell time determines the duration of a list step in list oper-
ating modes "Auto", "Single" and "Extern Single". In these modes a complete list is pro-
cessed either once or continuously.
In list operating modes "Step" and "Extern Step", the set dwell time does not affect sig-
nal generation. In this case, the duration of a list step is determined by the time
between two (internal or external) trigger events.
The "Dwell Time" set by the user is used as the step time of the list mode. The effec-
tive net dwell time is shorter, reduced by the setting time. This setting time may be
greater than the time specified in the data sheet.
Remote command:
Current Index - List Mode
Sets the list index in "Step" mode.
Remote command:
Blank RF Output (Default ON) - List Mode
Activates/deactivates RF output blanking. If activated, blanking occurs on all frequency
changes. If deactivates, blanking is always disabled.
Remote command:
Learn List Mode Data... - List Mode
Starts the determination of the hardware setting for the selected list. The data deter-
mined in this way is stored along with the list.
It may be necessary to deliberately activate list learning in the event of greatly altered
environmental conditions that require new hardware settings.
If this is not done, a previously learned hardware setting will continue to be used when
list mode is switched on ("State = On"). If no setting is available, e.g. when the list is
used for the first time, learning is automatically activated.
RF Signal and Analog Modulations - RF Block
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...