Remote Control Commands
R&S
®
SMJ100A
701
Operating Manual 1403.7458.32 ─ 14
Return values:
<MLevel>
string
Example:
SOUR:CORR:CSET:DATA:POW:MLEV4?
queries the level correction values for attenuator setting 10 dB.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:CORRection:CSET:DATA:POWer:MLEVel:STATe
<State>
The command activates the acquisition of multi level data with a connected power sen-
sor. Separate measurements are made for the different attenuator ranges up to 40 dB.
Thus, the changes in VSWR for the different ranges are taken into account, the level
accuracy increases. For ranges from 40 dB on the changes in VSWR are negligible.
The reference level is set internally and cannot be controlled by the user. The mea-
surement results are entered into additional columns of the User Correction list. The
Multi Level Correction measurements are made in addition to a Single Level Correction
measurement. When the user correction list is activated, it is possible to select which
of the measurements is to be used for level correction (command
SOUR:CORR:MLEV:STAT ON
).
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
SOUR:CORR:CSET:DATA:POW:MLEV:STAT ON
activates the acquisition of multi level data with a connected
power sensor.
Manual operation:
See
[:SOURce<hw>]:CORRection:CSET:DATA:POWer:SGAMma:STATe
<State>
Activates the auto fill process to create a list with SGamma correction data.
SGamma correction is possible when the table is filled with multi level user correction
data.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
CORR:CSET:DATA:POW:SGAM:STAT ON
activates the acquisition of multi level gamma correction data
with a connected power sensor.
[:SOURce<hw>]:CORRection:CSET:DATA:SGAMma:DELete
Deletes SGamma correction values in the selected table.
SOURce Subsystem
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...