Preparing for Use
R&S
®
SMJ100A
58
Operating Manual 1403.7458.32 ─ 14
Setting up the VNC connection on the Windows remote computer
1. Start VNC Viewer program component on the PC, select "VNC Server" and enter
IP address of the instrument.
2. To initialize the connection, select "Connect".
A message requesting the password appears.
3. Enter the password as defined in the "Default Local System Properties" panel of
the Ultr@VNC program and select "Log On".
The connection is established, the instrument is remote accessed and the current
signal generator screen with the block diagram is displayed. The individual func-
tions are operated using the mouse and keyboard.
Enabled Direct Control
The direct control of the instrument is not disabled and the instrument can be control-
led from the front panel and via the remote computer alternately.
Terminating VNC Connection
The remote access via VNC connection can be terminated either on the R&S
SMJ or
on the external PC. Terminating the connection does not disable it. It can be estab-
lished again any time. See the notice above concerning unauthorized access due to
VNC connection!
1. Terminate the connection on the R&S
SMJ
a) Press the "Windows" key to access the operating system.
b) Right-click on the VNC icon on the task bar and select "Kill all clients".
2. To terminate the connection on the external Linux/Unix PC, close the internet
browser or close the signal generator window.
Remote Access via an External Controller
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...