Instrument Function
R&S
®
SMJ100A
156
Operating Manual 1403.7458.32 ─ 14
"Path..."
Selects the directory.
Note:
To select the destination path, you have to specify a file name
as well. Otherwise an error message is displayed and the selection is
canceled.
Directory, path and file name are displayed in the infoline right to the
"Path" button.
Remote command:
:HCOPy:FILE[:NAME]:AUTO:DIRectory
"Clear Path"
Deletes all image files with extensions
bmp
,
img
,
png
,
xpm
and
csv
in the directory set for automatic naming.
Before deleting the image files a warning message is displayed
requiring the confirmation.
Remote command:
:HCOPy:FILE[:NAME]:AUTO:DIRectory:CLEar
"Prefix, Year,
Month, Day"
Determines the rules for "Automatic Naming".
Per default, the automatically generated file name is composed of:
<Path>/<Prefix><YYYY><MM><DD><Number>.<Format>
, where
Y
,
M
and
D
mean Year, Month, Day;
Number
is the "Current Auto
Number".
You can deactivate/activate each component separately.
The "Resulting File Name" indicates the current file name syntax.
Remote command:
:HCOPy:FILE[:NAME]:AUTO[:FILE]:PREFix:STATe
:HCOPy:FILE[:NAME]:AUTO[:FILE]:PREFix
:HCOPy:FILE[:NAME]:AUTO[:FILE]:YEAR:STATe
:HCOPy:FILE[:NAME]:AUTO[:FILE]:MONTh:STATe
:HCOPy:FILE[:NAME]:AUTO[:FILE]:DAY:STATe
"Current Auto
Number"
Indicates the number which is used in the automatically generated file
name.
Note:
When initially switching on the instrument the number is reset
to the lowest possible value. Starting with number 0 the output direc-
tory is scanned for already existing files. As long as files with the
same name are existing the number is increased by 1. The number is
automatically set so that the resulting file name will be unique within
the selected path. The current number is not in the save/recall file but
will be temporarily stored within the database. At following save oper-
ations the number is increased.
Remote command:
:HCOPy:FILE[:NAME]:AUTO[:FILE]:NUMBer?
"Resulting File
Name"
Indicates the automatically generated file name.
Remote command:
General Instrument Settings
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...