Remote Control Commands
R&S
®
SMJ100A
762
Operating Manual 1403.7458.32 ─ 14
Parameters:
<Source>
INTernal | EXTernal | INT,EXT
INTernal
Uses the internally generated signal for modulation. To configure
the LF signal, use the commands of the
subsystem.
EXTernal
Uses an externally applied modulation signal.
INT,EXT
Uses both, the internal and external modulation signals.
*RST:
INT
Example:
PM:SOUR INT
selects the internal modulation source.
Manual operation:
See
[:SOURce<hw>]:PM:STATe
<State>
Activates phase modulation.
Note:
Activation of PM deactivates frequency modulation (FM).
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
PM:STAT ON
activates PM.
Manual operation:
See
7.16.15 SOURce:POWer Subsystem
This subsystem contains the commands for setting the output level, level control and
level correction of the RF signal.
Other units can also be used instead of dBm:
●
by entering the unit directly after the numerical value (example
:POW 0.5V
)
●
by changing the DEFault unit in the
UNIT
system (see the command
............................................................................. 763
.............................................................................. 763
[:SOURce<hw>]:POWer:ALC[:STATe]
............................................................................. 763
[:SOURce<hw>]:POWer:ATTenuation:RFOFf:MODE
.........................................................764
...............................................................................764
[:SOURce<hw>]:POWer[:LEVel][:IMMediate][:AMPLitude]
..................................................765
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:OFFSet
........................................................765
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:RCL
.............................................................766
[:SOURce<hw>]:POWer:LIMit[:AMPLitude]
.......................................................................766
SOURce Subsystem
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...