Instrument Function
R&S
®
SMJ100A
376
Operating Manual 1403.7458.32 ─ 14
HDD Streaming
Enables/disables the streaming of modulation data direct form the hard drive (HDD).
HDD streaming is recommended for processing of large files that require more ARB
memory than the currently installed one.
HDD Streaming is enabled for waveform with"Clock Freq." <= 1
MHz and "Number of
Samples" > 16
MS.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WAVeform:HDDStreaming:STATe
Streaming Buffer
(enabled for waveform with "Clock Freq." <= 1MHz and "Number of Samples" > 16MS)
Displays the filling level of the streaming buffer.
During normal operation, the streaming buffer level should have a value of 90% ..
100%. Buffer level around 0% indicates a buffer underrun and the signal processing
will be interrupted.
Adjustment in the parameter value or state usually results in short decreasing of the
streaming buffer level but this buffer state should not be misunderstood as buffer
underrun.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WAVeform:HDDStreaming:BLEVel?
Clock Frequency
Displays or enters the ARB output clock rate.
When the waveform file is loaded, this value is automatically set to the clock rate
defined in the file (Clock tag). The user can subsequently alter the value if necessary.
When intending to work with an external clock source, the frequency to be applied
must be entered here.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:CLOCk
Trigger/Marker
Calls the Trigger and Marker menu.
This menu is used to select the trigger source, set the time delay on an external trigger
signal and configure the marker output signals (see
"Trigger/Marker/Clock Settings"
Remote command:
n.a.
Execute Trigger
Executes trigger manually. A manual trigger can be executed only when an internal
trigger source and a trigger mode other than Auto are selected.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute
Baseband Signal - Baseband Block
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...