Remote Control Commands
R&S
®
SMJ100A
559
Operating Manual 1403.7458.32 ─ 14
........................................................................................ 565
:SENSe<ch>[:POWer]:OFFSet:STATe
............................................................................. 565
.................................................................................... 565
.......................................................................................566
SENSe<ch>[:POWer]:STATus[:DEVice]?
......................................................................... 566
....................................................................................566
..........................................................................................567
.......................................................................................... 567
............................................................................................567
:SENSe<ch>[:POWer]:APERture:DEFault:STATe
<UseDefAp>
Deactivates the default aperture time of the respective sensor.
To specify a user-defined value, use the command
Parameters:
<UseDefAp>
0 | 1 | OFF | ON
*RST:
1
Example:
SENS:POW:APER:DEF:STAT 0
deactivates the default aperture time of the sensor.
Manual operation:
See
:SENSe<ch>[:POWer]:APERture:TIMe
<ApTime>
Defines the aperture time (size of the acquisition interval) for the corresponding sensor.
Parameters:
<ApTime>
float
Range:
depends on connected power sensor to depends
on connected power sensor
Increment: 1E-9
*RST:
depends on connected power sensor
Example:
SENS:POW:APER:TIM 23ms
sets 23 ms aperture time.
Manual operation:
See
:INITiate<ch>[:POWer]:CONTinuous
<Continuous>
The command switches the local state of the continuous power measurement by the
R&S NRP-Zxx power sensors on and off. Switching the local state off enhances the
measurement performance during remote control
The remote measurement is triggered by the READ query (command
on page 560) which also provides the measurement results. The local
state is not influenced by this command, measurements results can be retrieved with
local state on or off.
SENSe, READ and INITiate Subsystems
Содержание SMJ100A
Страница 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Страница 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Страница 139: ...Manual Operation R S SMJ100A 123 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 140: ...Manual Operation R S SMJ100A 124 Operating Manual 1403 7458 32 14 Legend of Front Panel Controls...
Страница 454: ...Instrument Function R S SMJ100A 438 Operating Manual 1403 7458 32 14 Baseband Signal Baseband Block...
Страница 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Страница 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Страница 843: ...Hardware Interfaces R S SMJ100A 827 Operating Manual 1403 7458 32 14 Figure A 2 BERT circuit diagram BERT Connector...
Страница 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...