3152B User Manual
Publication No. 980935 Rev. A
5-94 Programming Reference
EADS North America Test and Services
Table 5-11, Digital Pulse Commands Summary
Keyword
Parameter Form
Default
3152A
HS
:DPULse
:DELay
0 to 10
0
0143A
:DOUBle
[:STATe]
OFF | ON | 0 | 1
0
0144A
:DELay
0
to
1e3
1e-3
0145A
:LEVel
:HIGH
-7.992
to
8
5
0147A
:LOW
-8
to
7.992
0
0148A
:HIGH
0 to 1e3
1e-3
0146A
:POLarity
NORMal | COMPlement | INVerted
NORM
0186A
:PERiod
80e-9 to 1e6 (80e-9 to 2/4e6 with option 1/2)
10e-3
0149A
:TRANsition
[:LEADing]
0
to
1e3
1e-3
0151A
:TRAiling
0
to
1e3
1e-3
0152A
DPULse:DELay <delay>(?)
HS Syntax: 0143A<float>(?)
Description
Programs the delayed interval of which the output idles on the low level amplitude until the first transition to
high level amplitude.
Parameters
Name
Range
Type
Default
Description
<delay>
0 to 10
Numeric
0
Sets the delay time interval in units of seconds. Note
that the sum of all parameters, including the pulse
delay time must not exceed the programmed pulse
period and therefore, it is recommended that the pulse
period be programmed first and then all other pulse
parameters.
Response
The 3152B returns the pulse delay value in units of seconds.
DPULse:DOUBle {OFF|ON|0|1}(?)
HS Syntax: 0144A<0|1>(?)
Description
This command turns the double pulse mode on and off. The double pulse mode duplicates the first pulse
parameters at a delayed interval set by the double pulse delay value.
Parameters
Range
Type
Default
Description
0-1
Discrete
0
Sets the double pulse mode on and off
Response
The 3152B returns 0 or 1 depending on the current double mode setting.