3152B User Manual
Publication No. 980935 Rev. A
±
25% of amplitude to 15 MHz;
THD
0.1%, 10 Hz to 100 kHz
Harmonics
<-47 dBc, 100 kHz to 1 MHz (10 Vp-p)
<-40 dBc, 1 MHz to 10 MHz (10 Vp-p)
<-37 dBc, 10 MHz to 15 MHz (10 Vp-p)
General
Physical Size
1/2 high, "C" module
Power Requirements
+24 VDC - 350 mA
-24 VDC - 350 mA
+12 VDC - 55 mA
-12 VDC - 55 mA
<19 W at full power
Signal Ground
Grounded to case ground
EMC Certification
CE marked
Safety
Designed to meet IEC EN61010-1, UL 3111-1
Workmanship Std.
Conform to IPC-A-610D
Environmental
Operating Temperature 0
°
C to 50
°
C, RH 80% (non-condensing)
Storage Temperature
-30
°
C to 80
°
C
B-2 3201/3202A Module Specifications
EADS North America Test and Services
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com