SEQuence:DELete <sequence_# >
HS Syntax: 13201<integer>
Description
This command deletes a step in the selected sequence table. Before using this command, be sure that the
correct sequence for deleting is selected.
Parameters
Name
Range
Type
Default Description
<sequence_# > 1 to 4096 Numeric (integer
only)
1
Selects the sequence number that will be deleted.
SEQuence:DELete:ALL
HS Syntax: 13210
Description
This command deletes the entire sequence table.
OUTPut:SYNC:TYPE {LCOMplete|BIT }(?)
HS Syntax: 0108A<0|1>(?)
Description
Programs the 3152B SYNC output source for sequenced mode.
Parameters
Name
Type
Default
Description
LCOMplete
Discrete
LCOM
The sync output transitions to high at the beginning of
the selected sequence step and transitions to low at the
end of the sequence minus 16 waveform periods.
BIT
Discrete
The sync output generates a pulse at the beginning of
the selected segment regardless of how many times the
segment appears in the sequence. The width of the
sync pulse is 16 waveform points.
Response
The 3152B returns LCOM or BIT depending on the current SYNC type.