Publication No. 980935 Rev. A
3152B User Manual
EADS North America Test and Services
Programming Reference 5-45
SPULse
Discrete
Selects the built-in pulse waveform.
RAMP
Discrete
Selects the built-in ramp waveform.
SINC
Discrete
Selects the built-in sinc waveform.
EXPonential
Discrete
Selects the built-in exponential waveform.
GAUSsian
Discrete
Selects the built-in gaussian waveform.
DC
Discrete
Selects the built-in DC waveform.
NOISe
Discrete
Selects the built-in noise waveform.
Response
The 3152B returns SIN, TRI, SQU, SPUL, RAMP, SINC, GAUS, EXP, DC, or NOIS depending on the current
3152B setting.
SINusoid:PHASe <phase>(?)
HS Syntax: 0700A<float>(?)
Description
Programs the start phase for the standard sine waveform. This command has no affect on modulated
waveforms.
Parameters
Name
Range
Type
Default
Description
<phase>
0 to 360
Numeric
0
Programs the start phase parameter in units of degrees.
Response
The 3152B returns the current start phase value.
SINusoid:POWer <power>(?)
HS Syntax: 0701A<integer>(?)
Description
Programs power for the sine
x
waveform. This command has no affect on modulated waveforms.
Parameters
Name
Range
Type
Default
Description
<power>
1 to 9
Numeric
1
Programs the power that the sine function will be raised
to. Note that even powers will provide waveforms that
are positive (all points >= 0) whereas odd powers will
provide functions that are positive or negative 50% of
the time.
Response
The 3152B returns the current power value for the sine
x
function.