Chapter 2: Service Menus
Accessing the DXi6900-S Service Menu
Quantum DXi6900-S Field Service Manual
33
1. Type the option for
Hardware Configuration
and press
<Enter>
.
The
Hardware Configuration Menu
).
Figure 22:
DXi6900-S Hardware Configuration Menu
*** Service Hardware Configuration Menu ***
0) Setup IPMI
>>> - Setup the iDRAC/IPMI.
1) Setup internal Storage
>>> - Setup the H730 attached storage.
2) Setup external Storage
>>> - Setup the NetApp RBOD/EBODs storage.
3) Factory Detect Hardware
- Create Factory List of Detected Hardware.
4) Encryption Tools
>>> - System wide Encryption for Disk Security.
The
Hardware Configuration Menu
includes the following options:
l
l
Setup Internal Storage on the next page
l
Setup External Storage on page 35
l
Factory Detect Hardware on page 37
l
Setup IPMI
Note:
In general, you should not use the
Setup IPMI
menu to change IPMI settings, as they are
already configured at the factory. You may need to change the IPMI settings if you are replacing the
Node system board (see
Replacing the Node System Board on page 126
).
The DXi6900-S system includes a standalone Intelligent Platform Management Interface (IPMI). The
Setup
IPMI Menu
allows you to configure the IPMI interface. You can either use the system defaults for the IPMI
IP address, or choose to enter customer-specific values. The User and Password are fixed, and cannot be
changed.
Default fields:
l
IP
-
10.17.21.51
l
Netmask
-
255.255.255.0
l
Gateway
-
10.17.21.254
l
User
-
admin
l
Password
-
Qa@Ip00!
To access the
Setup IPMI Menu
from the
Hardware Configuration Menu
:
1. Type the option for
Setup IPMI
and press
<Enter>
.
The
Setup IPMI Menu
)