Chapter 3: FRU Removal and Replacement Procedures
Replacing a Node Processor and Heatsink
Quantum DXi6900-S Field Service Manual
118
Figure 80:
Checking Processor and Heatsink Status
Removing a Failed Heatsink
To remove the heatsink from the DXi6900-S Node:
WARNING:
The heatsink and processor are hot to the touch for some time after the system has been
powered down. Allow the heatsink and processor to cool before handling them.
Turning Off the DXi6900-S on page 21
).
Opening and Closing the Node on page 63
).
3. Using a #2 Phillips screwdriver, loosen one of the heatsink retention sockets (see
). Wait 30 seconds for the heatsink to loosen from the processor.
4. Remove the screw diagonally opposite the screw you first removed.
5. Repeat step 4 for the remaining two screws.
6. Lift the heatsink away from the processor and set the heatsink aside.