Chapter 3: FRU Removal and Replacement Procedures
Replacing Node Cooling Fans
Quantum DXi6900-S Field Service Manual
82
l
Installing a Replacement Cooling Fan in the Node on the next page
Identifying a Failed Cooling Fan in the Node
The DXi6900-S Node contains six cooling fans that provide cooling for the processors, expansion cards,
and memory modules.
To identify the failed cooling fan:
1. Access the remote management console (see
Accessing Remote Management on page 21
).
2. Navigate to the
Status > Hardware > Details > System Board
page.
3. Note the number (1–6) of the cooling fan that has a
Failed
).
Figure 53:
Checking Fan Status
Removing a Failed Cooling Fan from the Node
To remove the failed cooling fan from the DXi6900-S Node:
Turning Off the DXi6900-S on page 21
).
Opening and Closing the Node on page 63
).
3. Identify the failed fan using the numbers on the cooling fan assembly.